| Nombre De La Marca: | XWELL |
| Número De Modelo: | XW-5V3A-512 |
| Cantidad Mínima De Pedido: | 1 Uds. |
| Precio: | USD 7900/pcs |
| Detalles De Embalaje: | caja de madera |
| Condiciones De Pago: | T/T, Unión Occidental, L/C |
512-Channel Battery Grading Machine For Lithium Cell Testing
Product Description
Configuration and material of complete sets of equipment:
1. XW series li-ion battery automatic testing and formation system 1 sets
2. Communication wire 1pcs
3. Power Line 1 pcs
4. Spare Part( details check spare part list) 1 set
5. Information File 1 pcs
The items inside the information file:
1. Software installation disk 1 pcs
2. Product qualification 1 pcs
3. Product quality tracking card 1pcs
4. Warranty card 1pcs
5. Spare part list 1 pcs
6. User guide 1 pcs
7. Drawing 1 set
Product Specification
|
Channel voltage and
current |
5V/3A
|
|||
|
Channel number
|
512 Channnels
|
|||
|
Parallel unit number per channel
|
1
|
|||
|
Input AC type
|
3 phase AC380V ±10%/50Hz
|
|||
|
Maximum input power
|
14KW
|
|||
|
Noise
|
≤65dB
|
|||
|
AC power supply wiring mode
|
Three-phase five wire connection
|
|||
|
The power factor of
power supply |
≥0.99(The load power is more than 30% of rated power)
|
|||
|
Total current distortion rate
|
THD≤5%
|
|||
|
Conversion efficiency
|
Each link conversion efficiency is more than 85%
|
|||
|
|
Constant voltage setting
range |
Charging:0.02V~5V
|
||
|
Minimum discharge voltage
|
Discharging:1V~5V
|
|||
|
Measuring range
|
0V~5V
|
|||
|
The voltage resolution
|
0.1mV
|
|||
|
Accuracy of control
|
±(0.05%RD+0.05%FS)
|
|||
|
Accuracy of measurement
|
±(0.05%RD+0.05%FS)
|
|||
|
|
Charging current setting range
|
0.02A~3A
|
||
|
Discharging current setting range
|
0.02A~3A
|
|||
|
Measuring range
|
0A~3A
|
|||
|
The current resolution
|
16 Bit AD,DA
|
|||
|
Accuracy of control
|
±(0.05%RD+0.05%FS)
|
|||
|
Accuracy of measurement
|
±(0.05%RD+0.05%FS)
|
|||
|
Temperature drift
|
25PPM/℃
|
|||
|
Power
|
Single channel maximum
output power |
30W
|
||
|
|
Channel sampling
time |
0.1s
|
||
|
Current response time
|
The maximum current rise time 20ms |
|||
|
Steps setting time range
|
1min~1024min
|
|||
|
Time
accuracy |
±0.01%
|
|||
XWELL factory
![]()
![]()
![]()
![]()
Cell grading machine package
![]()