| Nombre De La Marca: | XWELL |
| Número De Modelo: | El XW-32 |
| Cantidad Mínima De Pedido: | 1 Uds. |
| Precio: | USD 7900/pcs |
| Detalles De Embalaje: | CAJA DE MADERA |
| Condiciones De Pago: | T/T, Western Union, carta de crédito |
Battery scan function
Support barcode scanning, can scan one-dimensional code, two-dimensional code, sequence scan code, channel skip scan code, bound with the device channel information, easy to trace in the future. (Party B shall provide the wireless code scanning gun according to the barcode of the user)
1. Basic composition of equipment
The equipment is mainly composed of computer, communication interface and battery detection cabinet. The battery detection cabinet is composed of a fixture and a board for placing the fixture, a constant current and constant voltage source, a storage control circuit, a sampling circuit, a single-chip microcomputer and a control panel.
| Working power | Three-phase five-wire system AC380V±10%, 50HZ | ||
| Work environment | Temperature 0-40 degrees, relative humidity ≤80% | ||
| Heat dissipation | to enter the air naturally and exhaust the air upward | ||
| Overall energy saving | over 70% | ||
| Channel Parameter | |||
| Voltage measuring range | 0-5V, 1MV resolution | ||
| Battery voltage range | Charge 0-4.5V: Discharge 4.5-2V | ||
| Constant voltage range | 2.5V-4.5V | ||
| voltage accuracy | ±(1‰ reading +1‰ full) | ||
| Current accuracy | ±(1‰ reading +1‰ full) | ||
| Software Function | |||
| Control mode | Computer connection equipment work, FCL control | ||
| Communication mode | RS485 baud rate 57,600 | ||
| Process set | A maximum of 32 work steps and 256 cycles are se | ||
| Charging mode | Constant current, constant pressure | ||
| Charging cutoff condition | Voltage, current, time, capacity | ||
| Discharge | constant current | ||
| Discharge cut-off condition | Voltage, time, capacity | ||
| Defensive function | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc | ||
| Time range | Set it anywhere from 0 to 30,000 minutes | ||
| Time accuracy | ≤±1‰ | ||
| Sampling inspection period | ≤3S | ||
| Minimum frequency of data recording | ≤5S | ||
| Battery sorting | By capacity, time, discharge platform, etc | ||
| Data processing | Data, graphs, and loop diagrams | ||
![]()
![]()
XWELL can provide different fixtures for different types of cells
![]()
![]()